How to use this calculator
- Choose US customary or metric measurements.
- Enter the trench length, width, and depth.
- Enter the outside diameter of the drain pipe, or zero to ignore it.
- Add a waste allowance and calculate the stone volume.
How the calculation works
A French drain is a trench filled with drainage stone around a perforated pipe. The calculator finds the volume of the trench, subtracts the volume of the pipe laid inside it, and adds the allowance you choose. It reports stone volume only and does not size the trench or set the slope.
Formula
Trench = length × width × depth Pipe = π × (pipe diameter ÷ 2)² × length Stone with waste = (trench − pipe) × (1 + waste % ÷ 100)
Worked example
A 50 ft trench that is 12 in wide and 18 in deep holds 75 cubic feet. A 4 in pipe takes up 4.36 cubic feet, leaving 70.64 cubic feet of stone. With 10% waste the planning total is 77.70 cubic feet, or 2.88 cubic yards.
Second scenario: a longer trench
A trench 80 ft long, 10 inches wide, and 18 inches deep has a volume of 80 × 0.8333 × 1.5, which is 100 cubic feet. A 4 inch outside diameter pipe takes up π × (1/6)² × 80, about 6.98 cubic feet, leaving 93.02 cubic feet of stone. With a 10% allowance the planning total is 102.32 cubic feet, or 3.79 cubic yards.
Stone per 10 feet of trench
This table shows the trench volume for each 10 feet before the pipe is subtracted. A 4 inch pipe occupies about 0.87 cubic feet of every 10 feet, so subtract roughly that much for a 4 inch pipe.
| Width × depth | Cubic feet per 10 ft | Cubic yards per 10 ft |
|---|---|---|
| 10 in × 18 in | 12.50 | 0.46 |
| 12 in × 18 in | 15.00 | 0.56 |
| 12 in × 24 in | 20.00 | 0.74 |
| 18 in × 24 in | 30.00 | 1.11 |
What published guidance says about the build
Washington State University Extension describes a typical French drain as a trench about 1.5 feet deep and 10 to 12 inches wide, with a 4 to 6 inch perforated pipe, gravel on the sides and top, and filter fabric lining the sides. The Department of Energy Building America guide for footing drains calls for perforations facing down, at least 6 inches of washed gravel over the pipe and 2 inches below it, filter fabric around the gravel, and discharge to daylight at least 10 feet from the foundation. Those layers are why the stone quantity depends on where the pipe sits in the trench, not only on the trench size.
Mistakes that cause failures
- Leaving out fabric, so silt enters the stone and the drain clogs.
- Laying the pipe level or with the holes facing up. The pipe needs a consistent fall toward the outlet, and the outlet itself needs a place to drain.
- Sending water toward a neighbor or a foundation rather than away from both.
- Skipping the call before you dig. In the US, 811 is the free national service that arranges for buried utilities to be marked, and it asks for notice a few days ahead.
When to hire a drainage professional
A French drain moves water that reaches it. It does not make a poorly graded yard drain correctly. If you have water entering a basement, a high water table, or a wet area that is large relative to the trench, a drainage contractor or engineer can find the cause. A drain near a foundation can also affect the soil that supports it, so get advice before digging close to a house.
Project considerations
- Filter fabric, a soil or sand layer on top, and any section with a wider pipe are not included.
- The pipe must fit inside the trench, so the calculator stops if its diameter is larger than the trench width or depth.
- Trench size, slope, and outlet design depend on the site and the water to be moved, so follow your plans or a drainage professional.
- Ordering by volume avoids guessing density. Confirm quantity increments with the supplier.
Frequently asked questions
Should I enter the outside or inside diameter of the pipe?
Use the outside diameter, because that is the space the pipe takes up in the trench.
What if the pipe is wrapped in fabric?
Fabric takes almost no volume, so the result is still a good estimate. Measure the fabric separately if you need to buy it.